EngineSales@Perkins-Sabre.com     PartSales@Perkins-Sabre.com
 


PRODUCTS

Performance - 4.4TGM
Description Specifications Performance Equipment Installation Drawings
 
Engine speed
rev/min
Type of Operation Typical Generator Output (net) Engine Power Gross
kWe kVA kW bhp
1500 Prime Power
Standby (maximum)
50.8
55.8
63.5
69.8
56.4
62.0
75.6
83.1
1800 Prime Power
Standby (maximum)
57.2
63.0
71.6
78.8
63.6
70.0
85.3
93.9
 
Typical Fuel Consumption
rev/min 1500 rpm 1800 rpm
  litre/hr UK gall/hr litre/hr UK gall/hr
At 110% of power rating 15.8 3.48 18.0 3.96
At 100% of power rating 14.8 3.26 16.9 3.72
At 75% of power rating 10.2 2.24 13.2 2.90
At 50% of power rating 5.5 1.21 9.0 1.98
Note: All engine rating data based on operation under BS5514:1996, ISO 3046/1:1995 and DIN 6271 conditions.
 
Test Conditions
Air temperature 25°C (80.6°F), barometric pressure 100 kPa (29.5 in Hg), relative humidity 30%, maximum exhaust back pressure 6 kPa, maximum inlet restriction 3 kPa.

For operation outside of these conditions please consult your Perkins or Sabre Engines contact.

Performance tolerance quoted by Perkins is ±5%.

Electrical ratings assume a power factor of 0.8 and a generator efficiency of 90%.
 
Rating Definitions
Prime power: Power available at variable load in lieu of main power network. An overload of 10% is permitted for one hour in every twelve hours of operation.

Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.